Primax · Inverters · Hybrid
Primax NEXA PSE-DUAL-6KW Single Phase Hybrid Inverter
Model PSE-DUAL-6KW (NEXA)
Primax NEXA PSE-DUAL-6KW is a 6 kW single phase hybrid inverter with two MPP trackers, 9000 W maximum PV input and dual backup outputs each rated the full 6 kW. Maximum PV efficiency is 97.6% with a 120 A battery charge and discharge current, CAN and RS485 BMS communication, and RS485, CAN, Wi-Fi, Ethernet and 4G monitoring options.
Supplied and installed by Solar Works Pakistan across Punjab. For current pricing and availability, WhatsApp +92 336 666 4321.

Today's price and stock
Prices change every week. Tap below, add the quantity and your city, and we reply on WhatsApp with today's price and availability.
WhatsApp for today's priceKey features
- Two MPP trackers, 9000 W maximum DC input
- Two backup outputs, each rated 6000 W
- Max. PV efficiency 97.6%, European efficiency 97%
- Lithium or lead acid battery support, 120 A charge and discharge
- Communication: RS485, CAN, Wi-Fi, Ethernet, 4G
- Low noise operation, below 25 dB
- 10 year design life
PV input
| Max. DC input power | 9000 W |
|---|---|
| Max. DC input voltage | 500 V |
| MPPT voltage range | 150 - 450 V |
| Starting voltage | 125 V |
| Max. input current | 18 / 18 A |
| Max. short circuit current | 22.5 / 22.5 A |
| Number of MPP trackers | 2 |
AC output (grid)
| Rated output power | 6000 W |
|---|---|
| Max. output apparent power | 6600 VA |
| Rated output voltage | 220 / 230 / 240 V |
| Rated output frequency | 50 / 60 Hz |
| Max. output current | 27 A |
| THDi | < 3% |
| Output power factor | ~1 (-0.8 leading ~ +0.8 lagging) |
AC output (two backup)
| Full max. output power | 6000 W |
|---|---|
| Backup 1 max. output power | 6000 W |
| Backup 2 max. output power | 6000 W |
| Rated output voltage | 220 / 230 V |
| Rated output frequency | 50 / 60 Hz (±0.2%) |
| Max. output current | 27 A |
| Output power factor (off grid) | ~1 (0.8 leading to 0.8 lagging) |
| Output current harmonic distortion | THD < 3% (nonlinear load); THD < 1.5% (linear load) |
Battery parameters
| Battery type | Lithium or lead acid battery |
|---|---|
| Rated battery voltage | 48 V |
| Voltage range | 44 - 57 V |
| Max. charge / discharge current | 120 A |
| BMS communication | CAN / RS485 |
Efficiency
| Max. efficiency (PV) | 97.6% |
|---|---|
| Max. efficiency (cell) | 94.5% |
| European efficiency | 97% |
Protection
| PV input reverse polarity protection | Yes |
|---|---|
| PV insulation resistance detection | Yes |
| Residual current detection | Yes |
| Output over current protection | Yes |
| Output short circuit protection | Yes |
| Output over voltage protection | Yes |
General data
| Operating temperature range | -25 ~ 60 °C |
|---|---|
| Storage temperature range | -30 ~ 65 °C |
| Humidity range | 0 - 95% |
| Operating altitude | ≤ 4000 m |
| Communication | RS485 / CAN / WiFi / Ethernet / 4G |
| Noise | < 25 dB |
| Size (W × H × D) | 427 × 554 × 198 mm |
| Weight | 19 kg |
Standards
| Standards | EN 62109-1/2, IEC 62109-1/2, EMC 61000, EN 50549, VDE 4105/0124, NRS 097-2-1, IEC 61727 / 62116 / 61683 |
|---|