What you will see

  • Inverter stops at midday on bright days
  • FusionSolar shows 2034 or 2072
  • LED blinks red quickly (AC-side alarm)

Why it happens

When many homes on one transformer export together, voltage rises past the limit.

A long or thin AC cable adds to the voltage the inverter sees.

Diagram

Why it stops on bright afternoons

  1. 01Many homes export at midday
  2. 02Street voltage rises
  3. 03Inverter sees it above its limit (2034)
  4. 04Disconnects, recovers when normal

2072 is a short voltage spike. Limits change only with DISCO consent.

Huawei SUN2000 inverters; read the alarm ID and cause ID in FusionSolar.

What you can check yourself

  • Screenshot the alarm in FusionSolar with time and cause ID
  • Note whether it happens on sunny afternoons
  • Ask neighbours with solar if theirs stop too

What not to do

  • Do not ask anyone to raise limits without FESCO or LESCO consent
  • Do not keep switching the AC breaker

When to call us

  • Measure voltage at meter and inverter
  • Check AC cable size and joints
  • Prepare readings for a DISCO complaint

Midday voltage

High midday voltage is common on busy FESCO and LESCO transformers. Our Faisalabad and Lahore teams take readings so you can raise it with your DISCO.

Send us

FusionSolar alarm screenshots with times and the inverter model