What you will see

  • 2012 after panel changes
  • Lower generation than before

Why it happens

A shorter or shaded string has lower voltage, so the others push current back into it.

Diagram

Mismatched strings push current backwards

Matched

Same panel count and no heavy shade. Current flows forward.

Shorter or shaded string

Lower voltage, so others push current back: 2012.

Huawei SUN2000 inverters; read the alarm ID and cause ID in FusionSolar.

What you can check yourself

  • Note which input from the cause ID
  • Check for new shade on that part of the roof

What not to do

  • Do not rearrange strings yourself

When to call us

  • Count panels per string
  • Re-string so parallel strings match

Adding panels later

We redesign strings when Faisalabad and Lahore homes add panels to an existing Huawei system.

Send us

the alarm and roof layout photos