Solar Works Pakistan

Solis · Inverters · Hybrid

Solis S6-EH1P(3-8)K-L-PLUS Single Phase Hybrid Inverter

Model S6-EH1P3K-L-PLUS / 3.6K / 5K / 6K / 8K-L-PLUS

Solis single phase low voltage energy storage inverters in the S6-EH1P(3-8)K-L-PLUS series, covering 3 kW, 3.6 kW, 5 kW, 6 kW and 8 kW models. The PLUS range is generator-compatible to extend backup duration during a grid outage, supports multiple inverters operating together as a microgrid, offers dual backup ports for intelligent control of critical and non-critical loads, provides 10 seconds of 200% overload capability and switches over in under 4 ms for a seamless transition from grid to backup.

Supplied and installed by Solar Works Pakistan across Punjab. For current pricing and availability, WhatsApp +92 336 6664321.

Solis S6-EH1P(3-8)K-L-PLUS Single Phase Hybrid Inverter

Key features

  • Generator-compatible to extend backup duration during grid power outage
  • Multiple inverters can operate together to form a microgrid
  • Supports dual backup ports for intelligent control of critical and non-critical loads
  • 10 seconds of 200% overload capability
  • Automatic switchover time is < 4 ms, providing seamless transitions from grid to backup
  • Ensures excellent power supply stability, keeping the load unaffected by a weak grid or generator supply fluctuations

Input DC (PV side)

Recommended max. PV array size3K: 6 kW · 3.6K: 7.2 kW · 5K: 10 kW · 6K: 12 kW · 8K: 16 kW
Max. usable PV input power3K: 4.8 kW · 3.6K: 5.76 kW · 5K: 8 kW · 6K: 9.6 kW · 8K: 12.8 kW
Max. input voltage500 V
Rated voltage330 V
Start-up voltage90 V
MPPT voltage range90 - 435 V
Max. input current3K / 3.6K / 5K: 16 A / 16 A · 6K / 8K: 32 A / 32 A
Max. short circuit current3K / 3.6K / 5K: 20 A / 20 A · 6K / 8K: 40 A / 40 A
MPPT number / max. input strings number3K / 3.6K / 5K: 2 / 2 · 6K / 8K: 2 / 4

Battery

Battery typeLi-ion / Lead-acid
Battery voltage range40 - 60 V
Max. charge / discharge power3K: 3 kW · 3.6K: 3.6 kW · 5K: 5 kW · 6K: 6 kW · 8K: 8 kW
Max. charge / discharge current3K: 70 A · 3.6K: 80 A · 5K: 112 A · 6K: 135 A · 8K: 190 A
CommunicationCAN / RS485

Output AC (grid side)

Rated output power3K: 3 kW · 3.6K: 3.6 kW · 5K: 5 kW · 6K: 6 kW · 8K: 8 kW
Max. apparent output power3K: 3 kVA · 3.6K: 3.6 kVA · 5K: 5 kVA · 6K: 6 kVA · 8K: 8 kVA
Operation phase1/N/PE
Rated grid voltage220 V / 230 V
Rated grid frequency50 Hz / 60 Hz
Rated grid output current3K: 13.7 A / 13.1 A · 3.6K: 16.4 A / 15.7 A · 5K: 22.8 A / 21.8 A · 6K: 27.3 A / 26.1 A · 8K: 36.4 A / 34.8 A
Max. output current3K: 13.7 A / 13.1 A · 3.6K: 16.4 A / 15.7 A · 5K: 22.8 A / 21.8 A · 6K: 27.3 A / 26.1 A · 8K: 36.4 A / 34.8 A
Power factor> 0.99 (0.8 leading - 0.8 lagging)
THDi< 2%

Input AC (grid side)

Input voltage range187 - 253 V
Max. input current3K: 21 A · 3.6K: 25 A · 5K: 32 A · 6K: 40 A · 8K: 50 A
Frequency range45 - 55 Hz / 55 - 65 Hz

Output AC (back-up)

Rated output power3K: 3 kW · 3.6K: 3.6 kW · 5K: 5 kW · 6K: 6 kW · 8K: 8 kW
Max. apparent output power2 times of rated power, 10 s
Back-up switch time< 4 ms
Rated output voltage1/N/PE, 220 V / 230 V
Rated frequency50 Hz / 60 Hz
Rated output current3K: 13.7 A / 13.1 A · 3.6K: 16.4 A / 15.7 A · 5K: 22.8 A / 21.8 A · 6K: 27.3 A / 26.1 A · 8K: 36.4 A / 34.8 A
Max. AC passthrough current3K: 35 A · 3.6K: 35 A · 5K: 40 A · 6K: 40 A · 8K: 50 A
THDv (@linear load)< 2%

Efficiency

Max. efficiency96.2%
EU efficiency94.7%
Battery charged by PV / AC, max. efficiency95.3% / 94.5%
Battery discharged to AC, max. efficiency94.9%

Protection

Ground fault monitoringYes
DC reverse-polarity protectionYes
Integrated AFCI 2.0Optional
Protection class / over voltage categoryI / II (PV and BAT), III (MAINS, BACKUP and GEN)

General data

Dimensions (W × H × D)335 × 560 × 227 mm
Weight3K / 3.6K / 5K: 21.6 kg · 6K / 8K: 22.2 kg
TopologyHigh frequency isolation (for battery)
Operating ambient temperature range-40 ~ +60 °C
Ingress protectionIP66
Cooling conceptNatural convection · higher models: intelligent redundant fan-cooling
Max. operation altitude3000 m

Standards and certification

Grid connection standardNRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety / EMC standardIEC/EN 62109-1/-2, EN 61000-6-2/-3

Features

DC connectionMC4 plug (PV port) / terminal block (BAT port)
AC connectionTerminal block
DisplayLCD + Bluetooth + APP
CommunicationRS485, CAN; optional: Wi-Fi, GPRS, LAN