Solis · Inverters · Hybrid
Solis S6-EH1P(3-8)K-L-PLUS Single Phase Hybrid Inverter
Model S6-EH1P3K-L-PLUS / 3.6K / 5K / 6K / 8K-L-PLUS
Solis single phase low voltage energy storage inverters in the S6-EH1P(3-8)K-L-PLUS series, covering 3 kW, 3.6 kW, 5 kW, 6 kW and 8 kW models. The PLUS range is generator-compatible to extend backup duration during a grid outage, supports multiple inverters operating together as a microgrid, offers dual backup ports for intelligent control of critical and non-critical loads, provides 10 seconds of 200% overload capability and switches over in under 4 ms for a seamless transition from grid to backup.
Supplied and installed by Solar Works Pakistan across Punjab. For current pricing and availability, WhatsApp +92 336 666 4321.

Today's price and stock
Prices change every week. Tap below, add the quantity and your city, and we reply on WhatsApp with today's price and availability.
WhatsApp for today's priceKey features
- Generator-compatible to extend backup duration during grid power outage
- Multiple inverters can operate together to form a microgrid
- Supports dual backup ports for intelligent control of critical and non-critical loads
- 10 seconds of 200% overload capability
- Automatic switchover time is < 4 ms, providing seamless transitions from grid to backup
- Ensures excellent power supply stability, keeping the load unaffected by a weak grid or generator supply fluctuations
Input DC (PV side)
| Recommended max. PV array size | 3K: 6 kW · 3.6K: 7.2 kW · 5K: 10 kW · 6K: 12 kW · 8K: 16 kW |
|---|---|
| Max. usable PV input power | 3K: 4.8 kW · 3.6K: 5.76 kW · 5K: 8 kW · 6K: 9.6 kW · 8K: 12.8 kW |
| Max. input voltage | 500 V |
| Rated voltage | 330 V |
| Start-up voltage | 90 V |
| MPPT voltage range | 90 - 435 V |
| Max. input current | 3K / 3.6K / 5K: 16 A / 16 A · 6K / 8K: 32 A / 32 A |
| Max. short circuit current | 3K / 3.6K / 5K: 20 A / 20 A · 6K / 8K: 40 A / 40 A |
| MPPT number / max. input strings number | 3K / 3.6K / 5K: 2 / 2 · 6K / 8K: 2 / 4 |
Battery
| Battery type | Li-ion / Lead-acid |
|---|---|
| Battery voltage range | 40 - 60 V |
| Max. charge / discharge power | 3K: 3 kW · 3.6K: 3.6 kW · 5K: 5 kW · 6K: 6 kW · 8K: 8 kW |
| Max. charge / discharge current | 3K: 70 A · 3.6K: 80 A · 5K: 112 A · 6K: 135 A · 8K: 190 A |
| Communication | CAN / RS485 |
Output AC (grid side)
| Rated output power | 3K: 3 kW · 3.6K: 3.6 kW · 5K: 5 kW · 6K: 6 kW · 8K: 8 kW |
|---|---|
| Max. apparent output power | 3K: 3 kVA · 3.6K: 3.6 kVA · 5K: 5 kVA · 6K: 6 kVA · 8K: 8 kVA |
| Operation phase | 1/N/PE |
| Rated grid voltage | 220 V / 230 V |
| Rated grid frequency | 50 Hz / 60 Hz |
| Rated grid output current | 3K: 13.7 A / 13.1 A · 3.6K: 16.4 A / 15.7 A · 5K: 22.8 A / 21.8 A · 6K: 27.3 A / 26.1 A · 8K: 36.4 A / 34.8 A |
| Max. output current | 3K: 13.7 A / 13.1 A · 3.6K: 16.4 A / 15.7 A · 5K: 22.8 A / 21.8 A · 6K: 27.3 A / 26.1 A · 8K: 36.4 A / 34.8 A |
| Power factor | > 0.99 (0.8 leading - 0.8 lagging) |
| THDi | < 2% |
Input AC (grid side)
| Input voltage range | 187 - 253 V |
|---|---|
| Max. input current | 3K: 21 A · 3.6K: 25 A · 5K: 32 A · 6K: 40 A · 8K: 50 A |
| Frequency range | 45 - 55 Hz / 55 - 65 Hz |
Output AC (back-up)
| Rated output power | 3K: 3 kW · 3.6K: 3.6 kW · 5K: 5 kW · 6K: 6 kW · 8K: 8 kW |
|---|---|
| Max. apparent output power | 2 times of rated power, 10 s |
| Back-up switch time | < 4 ms |
| Rated output voltage | 1/N/PE, 220 V / 230 V |
| Rated frequency | 50 Hz / 60 Hz |
| Rated output current | 3K: 13.7 A / 13.1 A · 3.6K: 16.4 A / 15.7 A · 5K: 22.8 A / 21.8 A · 6K: 27.3 A / 26.1 A · 8K: 36.4 A / 34.8 A |
| Max. AC passthrough current | 3K: 35 A · 3.6K: 35 A · 5K: 40 A · 6K: 40 A · 8K: 50 A |
| THDv (@linear load) | < 2% |
Efficiency
| Max. efficiency | 96.2% |
|---|---|
| EU efficiency | 94.7% |
| Battery charged by PV / AC, max. efficiency | 95.3% / 94.5% |
| Battery discharged to AC, max. efficiency | 94.9% |
Protection
| Ground fault monitoring | Yes |
|---|---|
| DC reverse-polarity protection | Yes |
| Integrated AFCI 2.0 | Optional |
| Protection class / over voltage category | I / II (PV and BAT), III (MAINS, BACKUP and GEN) |
General data
| Dimensions (W × H × D) | 335 × 560 × 227 mm |
|---|---|
| Weight | 3K / 3.6K / 5K: 21.6 kg · 6K / 8K: 22.2 kg |
| Topology | High frequency isolation (for battery) |
| Operating ambient temperature range | -40 ~ +60 °C |
| Ingress protection | IP66 |
| Cooling concept | Natural convection · higher models: intelligent redundant fan-cooling |
| Max. operation altitude | 3000 m |
Standards and certification
| Grid connection standard | NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA |
|---|---|
| Safety / EMC standard | IEC/EN 62109-1/-2, EN 61000-6-2/-3 |
Features
| DC connection | MC4 plug (PV port) / terminal block (BAT port) |
|---|---|
| AC connection | Terminal block |
| Display | LCD + Bluetooth + APP |
| Communication | RS485, CAN; optional: Wi-Fi, GPRS, LAN |