What you will see

  • An alarm message in the Soluna app.
  • The battery LED blinking or yellow.
  • One battery in a parallel bank not working.
  • The app cannot connect the battery to Wi-Fi.

The three Soluna alarm levels

Soluna sorts battery alarms into three levels, from its Lyra 5K, 10K Pack and 32K Pack user manuals.

Diagram

Soluna alarm levels

Minor

Power limited, no action

Moderate

Power limited, no action

Protection

Battery shuts down, call

Soluna Lyra 5K, 10K Pack and 32K Pack alarm levels.
AlarmWhat it meansTypical cause
Minor alarm (level 1)Battery tells the inverter to limit charging or dischargingA reading such as cell voltage near its limit; no action needed
Moderate alarm (level 2)Charging or discharging power is limited furtherSame as level 1, closer to the limit; no action needed
Protection alarm (level 3)Battery shuts down; LED blinking or yellowA limit was reached: call for support
Wi-Fi connecting failureBattery cannot join your networkRouter on 5 GHz only; Soluna needs 2.4 GHz
Serial number not validApp cannot set up the systemRegistration issue: send us the serial
Battery not working in parallelOne battery does not join the bankCommunication or power cable, terminating resistor, address switch or firmware

Why it happens

Minor and moderate alarms are part of normal battery management: the battery is asking the inverter to slow down, for example when it is nearly full or hot. A protection alarm means the battery has switched itself off to protect the cells.

When batteries are connected in parallel, a loose communication or power cable, a missing terminating resistor, a wrong address switch or old battery firmware can stop one battery from joining the bank. These are installer checks.

Soluna battery safe owner checks

  • Read the alarm level in the Soluna app and on the inverter screen.
  • For a minor or moderate alarm, let the system recover. Charging power may be lower for a while.
  • For Wi-Fi problems, check that your router has a 2.4 GHz network.
  • If the app says the serial number is not valid, do not keep retrying. Send us the serial number.

What not to do

  • Do not open the battery cover or touch the power or communication cables.
  • Do not change battery or inverter settings yourself.

When to call an engineer

  • A protection-level alarm, or the battery has shut down.
  • One battery in a parallel bank is not working.
  • The battery needs a firmware update (done with Soluna's service tool).

Soluna support in Punjab

We support Soluna batteries in Faisalabad, Lahore and across Punjab, including banks installed by other companies.

Send us

A screenshot of the Soluna app alarm, the battery model and serial number, and the inverter model.