Solis · Inverters · On-grid
Solis-(100-125)K-5G Three Phase Grid-Tied Inverter
Model Solis-100K-5G / Solis-110K-5G / Solis-125K-HV-5G
Solis three phase grid-tied inverters from Ginlong Technologies Co., Ltd., covering the Solis-100K-5G, Solis-110K-5G and Solis-125K-HV-5G models. The range offers 10 MPPTs with a maximum efficiency of 99.0%, a DC/AC ratio above 150%, high power tracking density of 100 MPPT/MW, compatibility with bifacial modules and a night SVG function. Intelligent string monitoring, smart I-V curve scan, remote firmware upgrade and integrated AFCI protection are included, with built-in PID recovery and power line communication available as options.
Supplied and installed by Solar Works Pakistan across Punjab. For current pricing and availability, WhatsApp +92 336 6664321.

Key features
- Efficient: 10 MPPTs, max. efficiency 99.0%
- Efficient: > 150% DC/AC ratio
- Efficient: high power tracking density, 100 MPPT/MW
- Efficient: compatible with bifacial modules
- Smart: night SVG function
- Smart: intelligent string monitoring, smart I-V curve scan
- Smart: remote firmware upgrade with simple operation
- Safe: AFCI protection, proactively reduces fire risk
- Safe: built-in PID recovery for better module performance (optional)
- Safe: overvoltage load reduction and leakage current suppression technology, low failure rate
- Economic: globally recognised branded componentry for longer life
- Economic: power line communication (PLC) (optional)
- Economic: DC side supports "Y" connector
Input DC
| Max. input voltage | 1100 V |
|---|---|
| Rated voltage | 100K / 110K: 600 V · 125K-HV: 720 V |
| Start-up voltage | 195 V |
| MPPT voltage range | 180 - 1000 V |
| Max. input current | 10 × 26 A |
| Max. short circuit current | 10 × 40 A |
| MPPT number / max. input strings number | 10 / 20 |
Output AC
| Rated output power | 100K: 100 kW · 110K: 110 kW · 125K-HV: 125 kW |
|---|---|
| Max. apparent output power | 100K: 110 kVA · 110K: 121 kVA · 125K-HV: 137.5 kVA |
| Max. output power | 100K: 110 kW · 110K: 121 kW · 125K-HV: 137.5 kW |
| Rated grid voltage | 100K / 110K: 3/N/PE, 220 V / 380 V, 230 V / 400 V · 125K-HV: 3/PE, 480 V |
| Rated grid frequency | 50 Hz / 60 Hz |
| Rated grid output current | 100K: 152.0 A / 144.3 A · 110K: 167.1 A / 158.8 A · 125K-HV: 150.4 A |
| Max. output current | 100K: 167.1 A · 110K: 183.8 A · 125K-HV: 165.4 A |
| Power factor | > 0.99 (0.8 leading - 0.8 lagging) |
| THDi | < 3% |
Efficiency
| Max. efficiency | 100K: 98.7% · 110K / 125K-HV: 99.0% |
|---|---|
| EU efficiency | 100K: 98.3% · 110K / 125K-HV: 98.5% |
Protection
| DC reverse-polarity protection | Yes |
|---|---|
| Short circuit protection | Yes |
| Output over current protection | Yes |
| Surge protection | DC Type II / AC Type II (AC Type I optional) |
| Grid monitoring | Yes |
| Anti-islanding protection | Yes |
| Temperature protection | Yes |
| Strings monitoring | Yes |
| I/V curve scanning | Yes |
| Integrated AFCI | Yes (activation required) |
| Integrated PID recovery | Optional |
| Integrated DC switch | Yes |
| Integrated AC switch | Optional |
General data
| Dimensions (W × H × D) | 1065 × 567 × 344.5 mm |
|---|---|
| Weight | 91 kg |
| Topology | Transformerless |
| Self-consumption (night) | < 2 W |
| Operating ambient temperature range | -30 ~ +60 °C |
| Relative humidity | 0 - 100% |
| Ingress protection | IP66 |
| Cooling concept | Intelligent fan-cooling |
| Max. operation altitude | 4000 m |
Standards and certification
| Grid connection standard | VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, TOR, UNE 206006, UNE 206007-1, CEI 0-21, IEC 61727, DEWA |
|---|---|
| Safety / EMC standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4 |
Features
| DC connection | MC4 connector |
|---|---|
| AC connection | OT terminal (max. 185 mm²) |
| Display | LCD |
| Communication | RS485; optional: Wi-Fi, GPRS, PLC |