What you will see

  • Code 88 and the inverter stays off
  • Brown or melted marks on connectors or cable ends
  • Crackling sound near the panels or inverter

Why it happens

A poor contact in a DC connector heats up and can spark. Mixed connector brands, water ingress and rodent damage are common causes.

Diagram

Repair first, then clear

Good connection

ConnectorTight, dry
→
InverterRunning

Loose or burnt

ConnectorSparking
→
InverterCode 88, stopped

Clearing code 88 without a repair only hides the problem.

Applies to Sungrow inverters with arc detection.

What you can check yourself

  • From a safe distance, look for burn marks on visible cables and connectors
  • Note any rodent activity on the roof

What not to do

  • Do not clear the arc fault in the app before a repair
  • Do not touch or unplug DC connectors

When to call us

  • Isolate DC safely and inspect every connector and cable
  • Replace burnt parts with matching connectors
  • Clear the fault only after repair

Connector inspections

We inspect and replace damaged DC connectors on Sungrow systems in Faisalabad, Lahore and across Punjab, including systems fitted by other installers.

Send us

the fault screenshot and photos of any marks on cables