What you will see
- Backup cuts out when an AC, motor or pump starts
- ID110 during load-shedding
- ID094 and backup stays off for a long time
Why it happens
Motors and compressors draw a big surge when starting. Added to everything else on backup, it can exceed the hybrid's rating.
A short circuit in a backup circuit or wrong wiring on the LOAD port triggers ID094.
Starting surge tips backup over
ID094 is different: a short circuit on the backup port. After three, SOFAR waits 30 minutes.
What you can check yourself
- Note which appliance started when backup dropped
- Switch off heavy loads during load-shedding
- See our load division article
What not to do
- Do not keep restarting the same heavy load
- Do not connect grid wiring to the LOAD port
When to call us
- Review circuits on the backup board
- Find any short circuit on backup wiring
- Divide loads or size up the system
Summer load-shedding
ACs running through load-shedding cause most backup overloads in Faisalabad and Lahore. We plan backup circuits so they stay on.
Send us
a list of appliances on backup and Event List photos