What you will see

  • No AC Connection during load-shedding
  • No AC Connection while the rest of the house has power
  • Inverter restarts a few minutes after the grid returns

Why it happens

On-grid inverters must stop the moment the grid disappears so no solar power flows into lines being worked on. Only a hybrid such as SPH with a battery keeps backup loads on.

If the grid is present, the inverter is not receiving it at its AC terminals: a tripped breaker, loose connector or wiring fault.

Diagram

Error 302: normal or a problem?

Load-shedding

GridOff
→
On-grid inverterStops by design

Expected safety stop.

Grid is on in the house

GridOn
→
AC breakerOff or loose
→
InverterError 302

Needs a breaker and wiring check.

Only an SPH hybrid with battery and EPS wiring keeps loads on.

What you can check yourself

  • Check whether the house has grid power
  • Check the inverter's AC breaker is ON
  • Wait a few minutes after the grid returns

What not to do

  • Do not bypass anything to run an on-grid inverter in load-shedding
  • Do not connect a generator to the inverter output

When to call us

  • Check AC wiring and connector at the inverter
  • Check breaker and any voltage protector
  • Advise on a hybrid upgrade if you need backup

Load-shedding hours

On-grid Growatt systems across Faisalabad and Lahore show this every outage. If you want backup, we can survey your system for a hybrid upgrade.

Send us

a photo of the alarm with the time and whether the house had grid power