SolarMax SM-3.6K-H1P and SM-5K-H1P are single phase hybrid inverters for 48 V lead-acid or lithium batteries (see the SolarMax datasheets). Faults show as an F number on the screen and in the Device Info page. The table below comes from SolarMax's user manual for these models. For any brand, our guide on reading inverter fault codes explains the basics.

What SolarMax F codes mean, in plain words

The inverter checks the grid, the panels, the battery and its own temperature all the time. When a reading goes outside its safe range, it stops or limits output and shows a code. Many codes clear by themselves once the cause goes away; the manual's first step for most of them is to wait and check again.

Diagram

Where SolarMax faults come from

Grid side

F35, F42, F47, F48

Panel side

F20, F23, F24, F63

Battery and inside

F13, F18, F26, F56, F64

SolarMax SM-H1P hybrid codes grouped by where the problem usually is.

SolarMax SM-H1P error code table

CodeWhat it meansTypical cause
F13Working mode changeThe inverter changed its work mode; usually clears within a minute
F18AC over current (hardware)Backup or home load above the inverter rating
F20DC over current (hardware)Panel or battery connection
F23AC leakage currentLeakage on the panel or inverter cable, often after rain
F24DC insulation impedance failurePanel wiring insulation or the earth connection
F26DC busbar unbalancedInternal: often clears after a wait, call us if it repeats
F35No AC gridLoad-shedding, a tripped breaker or a loose grid connection
F42AC line low voltageLow local voltage or loose AC cables
F47AC over frequencyUnstable supply or generator
F48AC lower frequencyUnstable supply or generator
F56DC busbar voltage too lowBattery deeply discharged
F63Arc faultPanel cable or connector problem (detection is a US-market feature)
F64Heat sink high temperatureHot room, blocked airflow or dust

SolarMax safe owner checks

  • Photograph the screen and note the date and time. The Device Info page lists recent alarm codes.
  • During load-shedding, F35 (No AC grid) is normal. It clears when the supply returns.
  • Check whether your main breaker or a voltage protector has tripped.
  • For F18, switch off heavy loads on the backup output and see if the fault clears.
  • For F56, let the battery charge from solar or the grid before running loads again.
  • Keep the area around the inverter ventilated and free of dust. Never wash the inverter with water.

When to call an engineer

  • F18, F20 or F26 faults that repeat after a restart.
  • F23 or F24 (leakage or insulation), especially after rain or panel washing.
  • F42, F47 or F48 that happen every day: we measure the supply at the inverter and check the AC cables.
  • F63 (arc fault): switch off at the AC breaker and call us.
  • F64 that comes back in normal room temperature.

To restart, follow our safe restart steps.