This table is for the ABi-Solar GT 3K and GT 5K on-grid inverters and comes from ABi-Solar's user manual. When a warning occurs the screen shows "WR". The four warnings are: no PV module connected, flash memory failure, inverter start-up failure and fan failure (5 kW only).
ABi-Solar fault groups
Grid
22, 23, 24
Panels and earthing
9, 12, 13, 19
Inside the inverter
1 to 8, 10, 11, 14 to 18
ABi-Solar GT 3K and 5K fault code table
| Code | What it means | Typical cause |
|---|---|---|
| 1 | Bus overvoltage | Internal |
| 2 | Bus undervoltage | Internal |
| 3 | Bus soft-start timeout | Internal |
| 4 | Inverter soft-start timeout | Internal |
| 5 | Inverter overcurrent | Internal or grid disturbance |
| 6 | Over temperature | Hot location or dusty heat sink |
| 7 | Relay or voltage detector fault | Internal |
| 8 | Output current sensor failure | Internal |
| 9 | PV voltage too high | Too many panels in a string |
| 10 | Power failure | Internal supply |
| 11 | DC input overcurrent | Panel side |
| 12 | GFCI failure | Earth voltage too high |
| 13 | PV insulation failure | Damaged cable or wet connector |
| 14 | Inverter DC current high | Internal |
| 15 | MCU and DSP readings do not match | Internal |
| 16 | GFCI sensor failure | Internal |
| 17, 18 | MCU and DSP connection or communication failure | Internal |
| 19 | Ground loss | Earth not connected |
| 22 | Grid voltage lost or out of range | Load-shedding or weak supply |
| 23 | Grid frequency lost | Unstable supply |
| 24 | Islanding detected | Grid abnormal: waits for the grid |
ABi-Solar safe owner checks
- Photograph the code and note the time.
- A blank screen early in the morning or in the evening is normal: the panels do not have enough voltage yet.
- The inverter switching on and off on a cloudy day is normal.
- For code 6, let the inverter cool and clear dust from the heat sink. Do not use a pressure washer.
- For codes 22 to 24, check for load-shedding or a tripped main breaker.
What not to do
- Do not do the manual's breaker restart sequence yourself, because it includes switching the DC side. Ask your installer.
When to call an engineer
- Codes 1 to 5, 7, 8, 10, 11 or 14 to 18 that return after a restart.
- Codes 9, 12, 13 or 19: panel wiring and earthing checks.
- A blank screen in full sun.
ABi-Solar service in Punjab
We service ABi-Solar on-grid inverters in Faisalabad, Lahore and across Punjab.
Send us
A photo of the code, the model (GT 3K or 5K) and serial number, and when it happens.